+49 2181 / 75 6 75 - 0

PSU MRG-5700V4V 700W - High efficiency

item no.: A 2378

Not in stock
-- €
send inquiry for this product
  • Description
  • Specs
  • Downloads
  • Related Products

  • 700W / High efficiency
  • AC Inlet in each module
  • Best solution for: Server, Workstation, Storage System, IPC
  • SPECIFICATIONS:
    VOLTAGE: 90 ~ 264 VAC FULL RANGE
    DIMENSIONS: 200.00x150.00x86.00 (mm)
    7.87x5.91x3.39 (inch)
    FREQUENCY: 47 ~ 63 Hz.
    INPUT CURRENT: 9.0A @115V; 5 A @ 230 VAC
    INRUSH CURRENT: 35A @ 115V; 75A @230 VAC

    1.TOTAL OUTPUT OF +5V & +3.3V NOT EXCEED 190W

    2.TOTAL OUTPUT POWER NOT EXCEED 700W

    Output Voltage Output
    Current
    Min
    Output
    Current
    Max
    Output
    Current
    Peak
    Regulation
    Load
    Regulation
    Line
    Output Ripple &
    Noise Max [P-P]

     +5V

     1

     32

     

     ± 5%

     ± 1%

     50mV

     +12V

     1

     57

     

     ± 5%

     ± 1%

     120mV

     -12V

     0

     0.8

     

     ± 5%

     ± 1%

     120mV

     +3.3V

     1.0

     32

     

     ± 5%

     ± 1%

     50mV

     +5VSB

     0.1

     3.5

     

     ± 5%

     ± 1%

     50mV


    FEATURES:

    - TEMPERATURE RANGE: OPERATING 0°C ~ 40°C, STORAGE –20°C ~ 80°C

    - HOLD UP TIME: DC OUTPUT 12V MUST BE MAINTAIN 16 ms IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE

    - EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD

    - POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

    - OVER POWER PROTECTION: 100~180%

    - OVER VOLTAGE PROTECTION: +5V->5.7~6.5V, +3.3V->3.9~4.7V, +12V->13.3~14.3V

    - SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB

    - EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

    - FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL

    - SAFETY: TO MEET UL, CUL, TUV, RFI/EMI STANDARDS

    - REMOTE ON/OFF CONTROL

    - COOLING: TWO 40mm DC FANS (MODULE)


    REMARKS:

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.