+49 2181 / 75 6 75 - 0

PSU P2H-6400P / 400W / 2U single

item no.: A 2371

available soon
-- €
send inquiry for this product
  • Description
  • Specs
  • Downloads
  • Related Products

  • 400W
  • Active PFC (full range), meet IEC-1000-3-2 CLASS D
  • Best solution for: Server, Workstation, Storage System, IPC
  • Connector type: ATX 2.03, ATX12V(P4), EPS12V, WTX, AMD-GES
  • SPECIFICATIONS:
    VOLTAGE: 90 ~ 264 VAC FULL RANGE
    DIMENSIONS: 215.00x100.00x70.00 (mm)
    8.46x3.94x2.76 (inch)
    FREQUENCY: 47 ~ 63 HZ
    INPUT CURRENT: 8.0 A ( RMS ) FOR 110VAC
    4.0 A ( RMS ) FOR 220VAC
    INRUSH CURRENT: 60A MAX. FOR 110 VAC
    80A MAX. FOR 220 VAC

    TOTAL CURRENT OF +5V AND + 3.3V NOT EXCEED 35A

    TOTAL +5V AND +3.3V AND +12V POWER NOT EXCEED 328W

    Output Voltage Output
    Current
    Min
    Output
    Current
    Max
    Output
    Current
    Peak
    Regulation
    Load
    Regulation
    Line
    Output Ripple &
    Noise Max [P-P]

     +5V

     3

     25

     

     ± 5%

     ± 1%

     80mV

     +12V

     2

     28

     

     ± 6%

     ± 1%

     120mV

     -5V

     0

     0.5

     

     ± 10%

     ± 1%

     150mV

     -12V

     0

     0.5

     

     ± 10%

     ± 1%

     150mV

     +3.3V

     1

     20

     

     ± 5%

     ± 1%

     80mV

     +5VSB

     0.1

     2

     

     ± 5%

     ± 1%

     80mV


    FEATURES:

    - Active PFC (full range), MEET IEC-1000-3-2 CLASS D

    - 12V Max. Current :28A

    - TEMPERATURE RANGE: OPERATING 0? ~ 40?.

    - HUMIDITY:OPERATING:20%-95%, NON-OPERATING:10%-95%

    - REMARKS:85% IS NORMAL CONDITION AND 95% IS WITH SPECIAL COATING PROCESS

    - OVER POWER PROTECTION

    - OVER VOLTAGE PROTECTION

    - SHORT CIRCUIT PROTECTION

    - EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

    - SAFETY: UL, CSA, TUV

    - Remote on/off control

    - Cooling: ONE 60 mm DC Fan

    - Serial ATA optional


    REMARKS:

    *THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 175W; 5V & 3.3V &12V NOT EXCEED 384WATTS

    *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.