  • SPECIFICATIONS:
    VOLTAGE: 90 ~ 264 VAC FULL RANGE
    DIMENSIONS: 185.00x150.00x86.00 (mm)
    7.28x5.91x3.39 (inch)
    FREQUENCY: 47 ~ 63 Hz.
    STEADY-STATE CURRENT: 8/4A AT ANY LOW/HIGH RANGE INPUT VOLTAGE
    INRUSH CURRENT: 25A MAX. FOR 110 VAC , 50A MAX.FOR 220 VAC
    (AT 25°C AMBIENT COLD START)
    PFC: UP TO THE TARGET OF 95% @110V, FULL LOAD

    Output Voltage Output
    Current
    Min
    Output
    Current
    Max
    Output
    Current
    Peak
    Regulation
    Load
    Regulation
    Line
    Output Ripple &
    Noise Max [P-P]

     +5V

     1

     25

     

     ± 250mV

     ± 1%

     50mV

     +12V

     1

     41

     

     ± 600mV

     ± 1%

     120mV

     -12V

     0

     0.8

     

     ± 600mV

     ± 1%

     120mV

     +3.3V

     1

     25

     

     ± 165mV

     ± 1%

     50mV

     +5VSB

     0.1

     3.5

     

     ± 250mV

     ± 1%

     50mV


    FEATURES:

    - TEMPERATURE RANGE: OPERATING 0°C ~ 50°C; STORAGE TEMPERATURE: -20°C – 80°C

    - HOLD UP TIME: 16mS MINIMUM AT NOMINAL INPUT VOLTAGE

    - EFFICIENCY: TYPICAL >80% AT 115V, 25%~100% MAX LOAD

    - LEAKAGE CURRENT: 3.5 mA. MAX. AT NOMINAL VOLTAGE 250VAC

    - POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

    - OVER POWER PROTECTION: 110%~160%

    - OVER VOLTAGE PROTECTION: +3.3V->3.6~4.3V, +5V->5.5~6.5V, +12V->13.2~15.6V

    - OVER CURRENT PROTECTION: +3.3V->27.5~37.5A, +5V->27.5~37.5A, +12V->45.1~65.6A

    - SHORT CIRCUIT PROTECTION: +12V, -12V, +5VSB

    - SAFETY: TO MEET UL, TUV, CB, CCC, RFI/EMI STANDARDS

    - EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B

    - REMOTE ON/OFF CONTROL